Difference between revisions of "Programming FTDI devices"

From Tučňák Wiki
Jump to: navigation, search
Line 15: Line 15:
 
  Number Of Blank Devices = 0
 
  Number Of Blank Devices = 0
 
  Number Of Programmed Devices = 1
 
  Number Of Programmed Devices = 1
 +
 +
Change:
 +
* Device Type to FT232R
 +
* USB VID/PID to Own VID & PID
 +
* Vendor ID to A600
 +
* Product ID by table bellow
 +
* Manufacturer to OK1ZIA
 +
* Product Description by table bellow
  
 
{| border="1" cellpadding="3" cellspacing="0"
 
{| border="1" cellpadding="3" cellspacing="0"
Line 22: Line 30:
 
|-
 
|-
 
| Davac4
 
| Davac4
| A110
+
| E110
 
| Davac 4.x
 
| Davac 4.x
 
|-
 
|-
 
| Rotar4
 
| Rotar4
| A112
+
| E112
 
| Antenna rotator 4.x
 
| Antenna rotator 4.x
 
|-
 
|-
 
| USBIO
 
| USBIO
| A113
+
| E113
 
| USB GPIOs
 
| USB GPIOs
 
|-
 
|-
 
| HDKEYB
 
| HDKEYB
| A114
+
| E114
 
| HD44780 + Keyboard
 
| HD44780 + Keyboard
 
|}
 
|}
  
In Device Type combo choose FT232R. Change:
 
* USB VID/PID to Own VID & PID
 
* Vendor ID to A600
 
* Product ID by table above
 
* Manufacturer to OK1ZIA
 
* Product Description by table above
 
  
 
Verify entered data, press Ctrl+V and save configuration to file. Pres Ctrl+P to programm.  
 
Verify entered data, press Ctrl+V and save configuration to file. Pres Ctrl+P to programm.  

Revision as of 08:42, 4 April 2012

This page describes how to programm the FT232R chip for use in:

You need File:MProg3.5.zip (obsoleted by FT_Prog but always work.

Run MProg

MProg initial state

Disconnect all possible USB devices (can contain FTDI chip also). Connect your device with FT232R. Press Ctrl+N to create new programming template. Press Ctrl+C to scan. MProg responds in bottom box:

Number Of Blank Devices = 0
Number Of Programmed Devices = 1

Change:

  • Device Type to FT232R
  • USB VID/PID to Own VID & PID
  • Vendor ID to A600
  • Product ID by table bellow
  • Manufacturer to OK1ZIA
  • Product Description by table bellow
Device Product ID Product description
Davac4 E110 Davac 4.x
Rotar4 E112 Antenna rotator 4.x
USBIO E113 USB GPIOs
HDKEYB E114 HD44780 + Keyboard


Verify entered data, press Ctrl+V and save configuration to file. Pres Ctrl+P to programm.

In bottom box result appears:

Programmed Serial Number : FTVCZQUP
MProg device programmed

Replug the device. Run Control Panel and you'll see new device:

Control panel with new device